Review of U.S. Army Ionizing Radiation Dosimetry System (1986)

Chapter: 'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'

Previous Chapter: CHARACTERISTICS OF IONIZING RADIATIONS TO WHICH ARMY MILITARY AND CIVILIAN PERSONNEL ARE EXPOSED
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 37
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 38
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 39
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 40
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 41
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 42
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 43
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 44
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 45
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 46
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 47
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 48
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 49
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 50
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 51
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 52
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 53
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 54
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 55
Suggested Citation: "'EVALUATION OF THE CHARACTERISTICS AND ADEQUACY OF THE ARMY'S TLD SYSTEM'." National Research Council. 1986. Review of U.S. Army Ionizing Radiation Dosimetry System. Washington, DC: The National Academies Press. doi: 10.17226/19202.
Page 56
Next Chapter: RECOMMENDATIONS REGARDING PERSONNEL DOSIMETRY DATA THAT SHOULD BE OBTAINED, STORED, AND ACCESSED
Subscribe to Emails from the National Academies
Stay up to date on activities, publications, and events by subscribing to email updates.